Biömik® Services
Coil Restoration for Chilled Water Systems
Chilled Water Coil Restoration
Chiller-based cooling systems are used in large commercial and industrial systems. These systems usually service multiple large AHUs. The coils that reside inside the units have between 4 and 10 rows of tubes, making them 6 and 12 inches thick. They can also have a very tightly packed fin configuration. This size and configuration make it very difficult to clean the entire surface area of the coil effectively.
The Biomik Process has been specifically developed to optimize the thermal transfer surface of the coil. Optimized coils will improve airflow and deliver more BTUs to the service area. This will have a profound effect on the chilled water loop. The coil will become more efficient, squeezing more BTUs out of each gallon of chilled water that passes through it. The net effect is that fewer gallons of chilled water are required to meet the cooling load. This reduction of chilled water required is where energy savings materialize.
Biömik® Patented Coil Restoration
Dirty, fouled HVAC coils are one of the biggest unseen drains on system performance, energy efficiency, and indoor air quality. Over time, coils accumulate biological and industrial contaminants — including stubborn biofilm — that standard cleaning methods can’t effectively remove. Left unchecked, this buildup restricts airflow, reduces thermal transfer, drives up energy costs, and shortens equipment life.
Biömik® Patented Coil Restoration is a revolutionary service engineered to bring coils back to “like-new” performance without expensive equipment replacement. Our patented process blends cutting-edge biological science with advanced Clean-In-Place (CIP) methodology, using super-heated pressurized water and proprietary probiotic solutions to penetrate deep into all coil surfaces and eliminate the real culprits of performance loss — including resilient biofilms that traditional methods leave behind.
Key benefits include:
-
Restore Original Performance: Return airflow and heat transfer closer to design specifications, improving cooling capacity and system responsiveness.
-
Reduce Energy Costs: Optimized coils require fewer gallons of chilled water or less compressor work, lowering energy consumption and operating expenses.
-
Extend Equipment Life: Avoid costly capital expenditures on new coils or units by revitalizing existing assets and delaying replacement.
-
Scientifically Driven: Our process is backed by measurable performance improvements and can be paired with Measurement & Verification (M&V) services to document real energy gains.
Whether you’re managing chilled water systems, rooftop units, or industrial HVAC installations, Biömik’s patented restoration delivers a deeper, more effective clean — addressing both biological and industrial fouling at its source.
How it works:
1
Best-in-class Clean-in-Place (CIP) methodology that utilizes Superheated Pressurized Water.
This process is highly effective on both biological and Industrial fouling. Years of development have maximized cleaning ability while eliminating risk to the coils being optimized.
2
A Biological Solution to a Biological Problem
Think of our Probiotic coil products as tiny, active, multiplying cleaning machines. They actively enter and utilize natural biological processes to detach and remove the real enemy of coil performance.....BIOFILM
3
Quantifying performance gains and energy savings
Measuring the gains in air handler performance is a difficult and time-consuming task. A comprehensive approach that trends BTU output for a period before and after is the only sound way to determine the net benefit of the Biomik Process. These Measurement and verification (M&V) services can be added onto your project to help pll interestedarties understand the real benefits of your project.